Shure QLXD Headphones User Manual


 
18
Network Scan
The Network Scan feature automates frequency assignment by using a single receiver to scan and deploy frequencies to all networked receiver within the same
frequency band.
Network Scanning and Frequency Deployment
1. Connect receivers to an active Ethernet network. All receivers must be on the same subnet.
2. Prior to performing a network scan, turn on all receivers and allow 60 seconds for all receivers to join the network.
3. Choose a group or custom group for deployment on the receiver that will be used to initiate the network scan.
4. To start a network scan, press the
menu button and navigate to the network scan menu. Press enter.
5. When the scan is complete, the displays of receivers waiting for frequencies will flash.
6. Press
enter to deploy the frequencies or press menu to cancel the deployment.
7. The front panel LEDs on each receiver will blink when a deployed frequency has been assigned.
Note: Full frequency deployment may not occur if the number of receivers in the network exceeds the number of available frequencies in the selected group. Try another
group or rescan after turning off unused receivers.
Connecting to an External Control System
The receiver connects to external controls systems (AMX or Crestron) via Ethernet cables.
• Connection: Ethernet (TCP/IP; QLXD receiver is the client)
• Port: 2202
For a comprehensive list of command strings, visit: http://shure.custhelp.com/
Shure AXT600 Spectrum Manager Compatibility
QLX-D receivers are compatible with the Axient AXT600 Spectrum Manager. Networked receivers will appear in the device inventory and frequencies from the
Compatible Frequency List can be deployed and monitored by the Spectrum Manager. For more information regarding the Spectrum Manager, see the Axient System
Guide.
Using QLX-D with a Shure ULX-D System
Transmitters and receivers from QLX-D and ULX-D component groups can be paired to form audio channels.
To ensure functionality, use the following settings on receivers and transmitters:
• Encryption set to Off
• High Density Mode set to Off (ULX-D receiver)
• Manually tune the receiver and transmitter to the same frequency. IR sync between QLX-D and ULX-D components is not supported.
To create an audio channel, manually set the receiver frequency to match the frequency of the transmitter.