Russound CA-Series Stereo Amplifier User Manual


 
IR
GND
+12V
CH SEL
SEL3
SEL1
BAL
VOL
21365487
9
PUNCHDOWN TERMINALS
Figure 11 – Punchdown
Terminal on CA-KP.2
and CA-LCD
The CA-KP.2 and CA-LCD come with 110 punchdown termi-
nals. These terminals are quick, easy to install and provide a
strong connection. Punchdown terminals require the use of a
punchdown tool. One has been provided with this kit.
Press wires into punchdown terminal with punchdown tool
as shown in Figure 12.
Figure 12 – Punching Down Wires
INSTALLING THE KEYPADS
The best infrared remote performance is achieved with
the keypad away from any direct sunlight. Also consider
convenience when choosing a location.
Choose a place that is easily seen from the position where
a person is most likely to be located.
Check whether or not you can route the wire to the loca-
tion you have chosen.
Purchase retro-fit plastic junction boxes (min. 20 cubic
inches) or p-rings and cut in the boxes using a key-hole
saw or sheetrock knife/hand saw.
If you are installing the optional DSC keypad you will
need to use a double-gang electrical box. If you are
installing the CA-LCD, DSC and the optional DAN keypad
you will need to install a triple-gang electrical box.
If you feel uncomfortable cutting into your walls and
running wire through the walls, seek help from a profes-
sional installer or an electrician.
Route the wire to the junction box from the CA location.
If using 22 AWG wire, connect each wire to the correct
position 1 thru 8 using the included punchdown tool.
Refer to List 5.
If using CAT-5 wire, connect each wire to its correspon-
ding color labeled on the punchdown terminal.
Mount the keypad in the junction box and attach the
Decora plate.
The CA-KP.2 keypad has source labels for your conven-
ience. Insert the label in the keypad keeping the input
number in sequence with the source selected.
Repeat the above steps until all keypads are installed.
INSTALLING KEYPADS
IR
GND
+12V
CH SEL
SEL3
SEL1
BAL
VOL
21365487
CAT-5 or 8-conductor
22 AWG wire
BROWN
ORANGE
BLUE
GREEN
Connector on
CA-KP.2 or CA-LCD
IR
GND
+12V
CH SEL
SEL3
SEL1
BAL
VOL
21365487
Punchdown
Tool