SPECIFICATIONS
11
EN
GX3 GX5
SPECIFICATION SUBjECT TO CHANGE WITHOUT NOTICE.
OUTPUT POWER, 1 kHz, 0.1 % clipping
8Ω, both channels driven 300 W 500 W
8Ω, single channel driven 350 W 600 W
4Ω, both channels driven 425 W 700 W
4Ω, single channel driven 500 W 850 W
2Ω, both channels driven, 1% clipping 200 W 350 W
SIGNAL TO NOISE (20 Hz – 20 kHz) 100 dB
INPUT SENSITIVITY 1.2 Vrms
VOLTAGE GAIN AT 8Ω 32.2 dB 34.4 dB
OUTPUT CIRCUITRY Class B 2-tier Class H
POWER REQUIREMENTS (1/8 power, pink noise 6.3 A 6 A
at 4Ω 120 V AC)
DISTORTION (1 dB below rated power, 20 – 20 kHz) 8Ω, less than 0.05%
4Ω, less than 0.1%
FREQUENCY RESPONSE 20 – 20kHz, +0, -1dB
DYNAMIC HEADROOM, 4Ω 2dB
DAMPING FACTOR 100
INPUT IMPEDANCE Greater than 20K ohms (balanced or unbalanced)
MAXIMUM INPUT LEVEL +24 dB (16 Vrms)
INPUT CONNECTORS, each channel 3-pin XLR and 1/4” TRS, balanced, parallel
Phono, unbalanced
OUTPUT CONNECTORS, each channel Speakon®, 1/4”, Binding Posts
AMPLIFIER AND LOAD PROTECTION Short circuit, open circuit, thermal, RF protection
Load protected against DC faults
CONTROLS AND INDICATORS, FRONT PANEL Gain controls, 21 detents
Red Clip LEDs, proportional, 0.1% THD threshold.
Green Signal LEDs, threshold -35 dB
Blue Power LED, AC-on.
CONTROLS, REAR PANEL Full Range / Crossover switch
100 Hz, 3rd order LP (sub), 2nd order HP (top).
DIMENSIONS (HWD) 3.5” (2RU) x 19” x 10.1” (89 mm x 483 mm x 257 mm)
WEIGHT – Shipping / Net 30 / 25 lbs (13.5 / 11.5 kg) 31 / 26 lbs (14 / 12 kg)
AGENCY APPROVALS UL, CE, RoHS / WEEE compliant
SPECIFICATIONS
0.2
4.1
6.1
9.75
6.3
9.4
15.0
Operating Condition
Idle
8 + 8 ohms, 1/8 power (1)
8 + 8 ohms, 1/3 power (2)
8 + 8 ohms, full power (3)
4 + 4 ohms, 1/8 power (1)
4 + 4 ohms, 1/3 power (2)
4 + 4 ohms, full power (3)
44
904
1160
1109
1515
2105
2297
0.3
3.3
8.5
16.2
5.8
11.2
24.5
60
734
1456
1891
1160
2162
3754
AC amps BTU / hr AC amps BTU / hr
AC POWER CONSUMPTION 1/8 power, ohms (AC Current and Heating, 120Vac)
(1) 1/8 power represents typical operating conditions.
(3) Full power is breaker limited to short periods.
(2) 1/3 power represents peak program levels.
(4) For 230V, multiply AC current by 0.5. For 100V, multiply AC current by 1.25.
GX3 GX5