PROBLEM:
DISTORTED SOUND
Magnetic field from power supplies in equipment can
induce hum into cabling that is located in the field. If
hum is a problem, try relocating cabling so that is away
from power supplies, transformers and other magnetic
field producing devices.
TROUBLESHOOTING: DISTORTION, NO CHANNEL SEPARATION, HUM, HISS, FEEDBACK
INDICATION:
CLIP LED FLASHING
If the red clip
indicator flashes before the signal indicator does, the load impedance is abnormally low or shorted. Unplug each speaker
one-by-one
at the amplifier.
If the clip
LED goes out when you disconnect a cable, then that cable or speaker is shorted. Try another
cable and speaker to locate and/or remove the fault.
INDICATION:
CLIP INDICATOR NOT FLASHING
This could be caused by a faulty speaker or loose connection. Check the wiring and try another speaker.
The signal source may be clipping. Keep the amplifier gain controls at least halfway up (-10 dB or less) so that the source does not
have to be overdriven.
PROBLEM:
NO CHANNEL SEPARATION
Use a common AC ground connection for all audio equipment.
Check the input cables for broken ground (shield) connection.
Use balanced connections for the entire signal chain.
The design of the
amplifier eliminates internal hum fields, but
external transformers or other magnetic devices may cause hum.
Move cabling and signal sources to identify "hot spots" in the
system; then avoid those spots. Cables with faulty shielding are a
common entry point for hum. Use top quality cabling. Another
common source of magnetic fields are wall warts or pluggable
transformers; keep input wiring away from them.
Check the mode switch settings on the back of the amplifier. If the mode switches are set for BRIDGE or PARALLEL mode, there
will be no channel separation. The mode switches must be set for STEREO for each channel to operate independently.
Make sure other equipment in the signal path to the amplifier, such as mixers, preamps, etc., is set for stereo, not mono.
PROBLEM:
HISS
Unplug the input cables to the amplifier. If the hiss goes away, then the problem is with the equipment or cables leading to the
amplifier.
If the hiss is present with no audio input cables connected, check that the AC line cord is properly grounded at its connection to
the line. If the ground connection is OK and the hiss continues with no input cables connected, then the amplifier requires
servicing.
To keep the normal noise floor low, operate the primary signal source at full level, without clipping, and avoid boosting the
signal further between the source and the amplifier.
PROBLEM:
SQUEALS AND FEEDBACK
Microphone feedback should be controlled with mixer controls. If noise continues to build up with zero mic gain, there is
a serious fault in the signal processors or cables. Working in succession from the signal source towards the amplifier,
check each device in the signal path by reducing its gain or unplugging it.
PROBLEM:
HUM