18
LED BRIGHTNESS CONTROL
Your Plinius SA-103 has an internal LED brightness control that will adjust all three front panel LED’s. A
small flat bladed screwdriver can be used to adjust the brightness. The LED brightness control is a small
multi turn potentiometer and is located on the front of the main circuit board within the top cavity of the
amplifier, and is labelled VR3. Make sure you adjust the correct potentiometer, and remember to remove
the mains supply from the amplifier before making any adjustments.
Ecologic Jumper JP5 Error LED LED Adjuster VR7
SECTION OF SA-103 MAINBOARD SHOWING POSITION OF
E
COLOGIC JUMPERS AND LED BRIGHTNESS ADJUSTMENT POTENTIOMETER
MAINS/LINE FUSE
A Mains/Line fuse is fitted within the IEC Mains/Line socket on the rear of the amplifier. A small drawer at
the bottom of this socket may be removed (after the IEC plug is removed) by levering it out with a flat
blade screwdriver. The fuse fitted should be rated as specified on the rear panel.
In the unusual event that this fuse should blow, you must first establish the cause of this failure (such as
power surges, damaged mains cable etc.) before replacing the fuse with one of the same rating and type.
IMPORTANT: DO NOT FIT A FUSE WITH A HIGHER RATING.
TOWARDS
FRONT OF
AMPLIFIER