Philips TDA8586 Stereo Amplifier User Manual


 
2001 Jul 23 10
Philips Semiconductors Preliminary specification
Power amplifier with load detection and
auto BTL/SE selection
TDA8586
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134).
Note
1. A large reverse current will flow, therefore external protection is needed (fuse and reverse diode).
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
V
P
supply voltage operating 8 18 V
load dump protected;
see Fig.6
45 V
V
DIAG
voltage on diagnostic pin 18 V
I
OSM
non-repetitive peak output current 6A
I
ORM
repetitive peak output current 4A
V
rp
reverse polarity voltage note 1 6V
V
sc
AC and DC short-circuit voltage of output pins
across loads and to ground or supply pins
18 V
P
tot
total power dissipation 75 W
T
j
junction temperature 150 °C
T
stg
storage temperature 55 +150 °C
T
amb
operating ambient temperature 40 +150 °C
Fig.6 Load dump voltage waveform.
handbook, halfpage
MGL404
t
r
V
P
t
f
45 V
14.4 V
t (ms)
THERMAL CHARACTERISTICS
SYMBOL PARAMETER CONDITIONS VALUE UNIT
R
th(j-a)
thermal resistance from junction to ambient in free air 40 K/W
R
th(j-c)
thermal resistance from junction to case 2 K/W