Philips AZ1220 Radio User Manual


 
Problem
No sound /power
Volume not adjusted
Adjust the VOLUME
Power cord not securely connected
Connect the AC power cord properly
Batteries dead/ incorrectly inserted
Insert (fresh) batteries correctly
Headphones connected to the set
Disconnect headphones
CD contains non-audio files
Press
SEARCH or §
once or more skip
the data file to a CD audio track
Display does not function properly/No
reaction to operation of any of the con-
trols
Electrostatic discharge
Switch off and unplug the set. Reconnect after a
few seconds
00 indication
No CD inserted
Insert a suitable disc
CD badly scratched or dirty
Replace/clean CD (See Maintenance)
CD-R(W) is blank or the disc is not finalized.
Use a finalized CD-R(W)
Laser lens steam up
•Wait until lens has cleared
The CD skips tracks
CD damaged or dirty
Replace or clean CD
Shuffle or program is active
Switch off shuffle/program
Poor cassette sound quality
Dust and dirt on the heads, etc.
Clean deck parts, see Maintenance
Use of incompatible cassette types (METAL or
CHROME)
Only use NORMAL (IEC
I
) for recording
Recording does not work
Cassette tab(s) may be broken
Apply adhesive tape over the missing tab space
Troubleshooting
If a fault occurs, first check the points listed below before taking the set for repair.
If you are unable to remedy a problem by following these hints, consult your dealer or service centre.
WARNING: Do not open the set as there is a risk of electric shock. Under no cir-
cumstances should you try to repair the set yourself, as this will invali-
date the guarantee.
Important notes for users in the U.K.
Mains plug
This apparatus is fitted with an approved 13 Amp plug.To change a fuse in this type of
plug proceed as follows:
1. Remove fuse cover and fuse.
2. Fix new fuse which should be a BS1362 5 Amp, A.S.T.A. or BSI approved type.
3. Refit the fuse cover.
If the fitted plug is not suitable for your socket outlets, it should be cut off and an
appropriate plug fitted in its place. If the mains plug contains a fuse, this should have a
value of 5 Amp. If a plug without a fuse is used, the fuse at the distribution board
should not be greater than 5 Amp.
Note:The severed plug must be disposed of to avoid a possible shock hazard should it
be inserted into a 13 Amp socket elsewhere.
How to connect a plug
The wires in the mains lead are coloured with the following code: blue = neutral (N),
brown = live (L). As these colours may not correspond with the colour markings iden-
tifying the terminals in your plug, proceed as follows:
Connect the blue wire to the terminal marked N or coloured black.
Connect the brown wire to the terminal marked L or coloured red.
•Do not connect either wire to the earth terminal in the plug, marked E (or e) or
coloured green (or green and yellow).
Before replacing the plug cover, make certain that the cord grip is clamped over the
sheath of the lead - not simply over the two wires.
Copyright in the U.K.
Recording and playback of material may require consent. See Copyright Act 1956 and
The Performer’s Protection Acts 1958 to 1972.