Niles Audio SI-1650 Stereo Amplifier User Manual


 
25
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 1-760-710-0992
16 CHANNEL, FULLY CONFIGURABLE POWER AMPLIFIERS
CONFIGURATION AND SETUP TOOL
EQUALIZATION MAIN SELECTION –
MANUAL EQ SELECTION
Choose the Manual EQ sub-selection and the Manual EQ page is displayed. The
amplier channels are included in a single pull down list along with their names.
Note: If an odd numbered channel is set to 100 watts, it even numbered
adjacent channel will not be included in the pull down list (e.g. when channel 15
set to 100 watts, channel 16 will not be included in the pull down list).
1. Choose a channel from the pull down list to adjust its EQ parameters. The
current Room EQ Preset is displayed for the selected channel. If any manual
adjustments are made and saved, the room preset display changes to
“None”.
2. Select or deselect Loudness, Low Cut or High Cut and use the individual
arrow buttons to adjust volume, bass, midrange, treble, midrange center
frequency and midrange bandwidth for the selected channel.
3. Copy EQ Settings saves all manual EQ parameters for the selected channel
to a clipboard including loudness, low cut, high cut, volume, bass, midrange,
treble, midrange center frequency and midrange bandwidth.
4. Paste EQ Settings applies the saved clipboard settings to any other selected
channel.
5. Set Flat sets the selected channel to the default Flat Room EQ Preset and
volume at 0dB.
6. Select Save to save
Manual EQ settings to the
amplier’s memory.
FIGURE 14