Nady Systems GEQ131 Stereo System User Manual


 
6
7. IEC Power Cord Receptacle
This is used to connect the AC power source to your equalizer.
Power requirements: 115VAC, 60Hz
CAUTION: For new installations and portable sound systems,
or in any situation in which the AC power is suspect, it is wise to
confirm appropriate voltage and line polarity BEFORE connecting
the instrument to the power source.
8. Fuse Holder
This fuse holder contains an AC primary fuse. This fuse should be
replaced with the same type fuse when this is blown out. If they
continuously blow, stop replacing the fuse and refer servicing to
qualified personnel.
CAUTION: After checking the AC supply voltage, be sure that the
correct fuse is in the fuse holder. A 20mm glass tube 500mA 250V
fast-blow fuse should be used.
9. Input/Output Connectors
Balanced XLR and 1/4” TRS Inputs and unbalanced output jacks
for line level operation. Line level signals from - 18dBu to +18dBu
are considered normal. Do not directly connect microphones into
the equalizers. Microphones require a pre amp.
Note: Only one input and one output connector should be used at
a time.