SP1200 – 9
D: Room Combining—Zones
Note: This application provides independent source selection for each zone, or common input
source selection for both zones (room combining). Both DX8 Selection Remote Controls are used
to select Presets 1 and 2.
For example, Preset 1 might route the CD Player and the Zone A microphone to Zone A, and the
Cassette Player and the Zone B microphone to Zone B, to be used when the divider is in place
between the two zones. Preset 2 might route both microphones and the audio signal from the
laptop to both Zones A and B, to be used when the divider is removed between the two zones.
Each zone on both SP1200s are assigned the same AMP ADDRESS, so when “OFF” is selected
on one SP1200, the DX8 signal at the Mic/Line Input is routed to the SP1200 outputs. The local
input sources (Tuner and CD 5-Disc Changer) or the Global Background Music via the Expansion
I/O can be routed to the SP1200 outputs by selecting 1, 2, or 4 on the SP1200 front panel.
SP1200 SWITCH SETTINGS
12345678
0
I
ZONE A
AMBIENT MIC OFF/ON
OFF ON
DOWN
UP
AMP ADDRESS
INPUT 4 PRIORITY OFF/ON
MASTER/SLAVE
12345678
LOCAL
1234
REMOTE
1234
1234
SP1200 SWITCH SETTINGS
12345678
0
I
ZONE A
AMBIENT MIC OFF/ON
OFF ON
DOWN
UP
AMP ADDRESS
INPUT 4 PRIORITY OFF/ON
MASTER/SLAVE
LOCAL
1234
REMOTE
1234
1234
12345678
PHANTOM
PAGING
GAIN +40dB
MIC /LINE INPUT A
CAUTION: TO REDUCE THE
RISK OF FIRE REPLACE WITH SAME
TYPE FUSE AND RATING
115V 60Hz FUSE 115/ T4A 120 WATTS
230V 50Hz FUSE 23 0/T2 A 120 WATT S
1234
12345678
0
I
PROGRAM EQ
1234
ZONE A
GAIN +40dBPHANTOM
ON
THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC
"MACKIE.","MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE. COPYRIGHT ©2000 ALL RIGHTS RESERVED
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. • WOODINVILLE • WA • MADE IN USA • FABRIQUE AU USA
PARALLEL
INPUTS
G
+
–
CONTROL
GROUND
ALL CALL
DIRECT
R
OUTPUT
PROGRAM INPUTS
1234
PRIORITY
L
HIGH
U
+12–12
U
+12–12
LOWGAIN
+
-
HIGH 12kFREQMIDLOW 80H z
U
+15–15
U
+15–15
U
+15–15
1K
3K400
8k
250
HIGH
U
+12–12
U
+12–12
LOWGAIN
+
-
+
-
AMP IN
PRE OUT
PAGING MIC
EXPANSION IN EXPANSION OUT
AMP ADDRESS RS485 REMOTE
AMBIENT
MIC
MIC
VOX
RISK OF ELECTRIC SHOCK
DO NOT OPEN
REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
UTILISE UN FUSIBLE DE RECHANGE DE M
ÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
WAR NIN G:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
CAUTION
AVIS:
RISQUE DE CHOC ELECTRIQUE
— NE PAS OUVRIR
SERIAL NUMBER
MANUFACTURING DATE
ZONE A
OUTPUT SUITABLE
FOR CLASS 2 WIRING
100/70V/8
+
–
1
2
3
G
+
–
A
G
B
12345678
LOCAL
1234
REMOTE
1234
SP1200
MUSIC CONTROLLER
PHANTOM
PAGING
GAIN +40dB
MIC /LINE INPUT A
CAUTION: TO REDUCE THE
RISK OF FIRE REPLACE WITH SAME
TYPE FUSE AND RATING
115V 60Hz FUSE 115/ T4A 120 WATTS
230V 50Hz FUSE 23 0/T2 A 120 WATT S
1234
12345678
0
I
PROGRAM EQ
1234
ZONE A
GAIN +40dBPHANTOM
ON
THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC
"MACKIE.","MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE. COPYRIGHT ©2000 ALL RIGHTS RESERVED
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. • WOODINVILLE • WA • MADE IN USA • FABRIQUE AU USA
PARALLEL
INPUTS
G
+
–
CONTROL
GROUND
ALL CALL
DIRECT
R
OUTPUT
PROGRAM INPUTS
1234
PRIORITY
L
HIGH
U
+12–12
U
+12–12
LOWGAIN
+
-
HIGH 12kFREQMIDLOW 80Hz
U
+15–15
U
+15–15
U
+15–15
1K
3K400
8k
250
HIGH
U
+12–12
U
+12–12
LOWGAIN
+
-
+
-
AMP IN
PRE OUT
PAGING MIC
EXPANSION IN EXPANSION OUT
AMP ADDRESS RS485 REMOTE
AMBIENT
MIC
MIC
VOX
RISK OF ELECTRIC SHOCK
DO NOT OPEN
REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
UTILISE UN FUSIBLE DE RECHANGE DE M
ÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
CAUTION
AVIS:
RISQUE DE CHOC ELECTRIQUE
— NE PAS OUVRIR
SERIAL NUMBER
MANUFACTURING DATE
ZONE A
OUTPUT SUITABLE
FOR CLASS 2 WIRING
100/70V/8
+
–
1
2
3
G
+
–
A
G
B
12345678
LOCAL
1234
REMOTE
1234
SP1200
MUSIC CONTROLLER
Note: See CAUTION under
"Bus Assign" on page 13.
Note: See CAUTION under
"Bus Assign" on page 13.
B
REMOTE BUS
TRIM
BUS A
U
+20-20
A
TRIM
1
RECORD
AB
OUTPUTS
LOGIC I/O
TRIM
BUS B
U
+20-20
TRIM
2
TRIM
3
TRIM
4
TRIM
5
TRIM
6
TRIM
7
TRIM
8
M
I
C
G
A
I
N
060
–
+
SERIAL NUMBER
MANUFACTURING DATE
COMM PORT
DIRECT OUTPUTS
12345678
POWER
INPUT
22
-
28V DC,
3A MAX
23456781
–
+
G
G
+
–
MIC
LINE
LINELINELINE
MIC
LINE
MIC
LINE
MIC
LINE
MIC
LINE
MIC
LINE
MIC
LINE
MIC
LINE
MIC
DX8 DIGITAL MIXER
-
30dB +30dB
U
M
I
C
G
A
I
N
060
-
30dB +30dB
U
M
I
C
G
A
I
N
060
-
30dB +30dB
U
M
I
C
G
A
I
N
060
-
30dB +30dB
U
M
I
C
G
A
I
N
060
-
30dB +30dB
U
M
I
C
G
A
I
N
060
-
30dB +30dB
U
M
I
C
G
A
I
N
060
-
30dB +30dB
U
M
I
C
G
A
I
N
060
-
30dB +30dB
U
PHANTOM POWER
48V DC
12 1+5V
11G1
G
+
–
G
+
–
G
+
–
INPUTS
OUTPUTS
100
–
240V , 50/60Hz, 1A MAX
THE FOLLOWING ARE TRADEMARKS OR REGISTERED
TRADEMARKS OF MACKIE DESIGNS INC "MACKIE",
"MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE
CONCEIVED, DESIGNED, AND MANUFACTURED
BY MACKIE DESIGNS INC WOODINVILLE • WA • USA
MADE IN USA • FABRIQUE AU USA • COPYRIGHT ©1999
LISTED COMMERCIAL
AUDIO EQUIPMENT
9Z39
R
ON
CD Player
Zone A
Cassette Player
Zone B
70V Loudspeakers
Zone A
70V Loudspeakers
Zone A OutZone B Out
Laptop with
PowerPoint
®
Presentation
Audio
Remote Controls
Remote Controls
0
– 3
– 6
– 8
–10
– 5
– 10
– 15
– 20
– 25
– 30
– 40
Tuner
Zone B
Mic
Zone A
Mic
Global Background
Music via Expansion I/O
to Input 1
0
– 3
– 6
– 8
–10
– 5
– 10
– 15
– 20
– 25
– 30
– 40
CD 5-Disc Changer
102.5
ZONE A/B
COMBINED
Zone B
Divider