Krell Industries KAV280p Stereo Amplifier User Manual


 
Back Panel Description, continued
10 Krell KAV–280p
17 12 VDC In
The KAV–280p is equipped with an input that receives 12 VDC
(12 V trigger) power on/off signals from other Krell components
and other devices that incorporate a 12 V trigger. This allows you
to turn the KAV–280p on or off, or to and from stand-by, from other
components.
The 12 VDC output current is limited to 30 ma.
Consult the owner’s reference of the components used in a custom
installation to take full advantage of the remote capability of the
KAV–280p.
18 RC-5 In
The KAV–280p is equipped with an RC-5 input that makes custom
installation easy and secure by accepting baseband RC-5 input
commands from hardwired remote controllers.
19 Line Fuse and Fuseholder
The 50/60 Hz line fuse protects the KAV–280p in the event of a
component failure.
The fuseholder drawer houses two line fuses: one is functional
and one is a spare.
When the line fuse needs to be replaced, use the spare fuse provided.
Unplug the component before replacing the fuse. Use a 0.5A, slow-blow,
5 x 20 mm fuse for 100-120 VAC, or a 0.25A, slow-blow, 5 x 20 mm fuse
for 220-240 VAC.
20 IEC Connector
The connector is for use with the provided IEC standard 15 amp
power cord.
POWER
Note
Notes
BACK PANEL REMOTE
CONNECTIONS,
continued