Dayton SPA1200/2400DSP Home Theater System User Manual


 
DSP Funcons
(20)
Feature Controller (LCD mat rix, single -knob, bezel mounted)
a) Volume: Range: 0 ~ -100dB, Step: 1dB
b) High pass Filter:
o Frequency Select: 31.5Hz ~ 125Hz, Step: 1 / 6 Oct. Slope: Flat/-12dB/-24dB
A. Low pass Filter:
a) Frequency Range: 31.5Hz ~125Hz, Step: 1 / 6 Oct.
b) Slope: Flat/-12dB/-24dB
c) Variable Phase: Range: 0° ~ -180°, Step: -5°
d) High Pass Delay: Delay Time Range: 0ms ~ 10ms, Step0.1ms
B. Room Gain Comp (Deleted with room auto-EQ):
a) Enable/Disable
b) FREQ: 25/31/40 Hz
c) Slope:-6/-12dB/Oct.
C. Subwoofer tune mode: Sealed/16Hz/20Hz/25Hz
D. Three-band Parametric EQ
a) Frequency Range: 31.5Hz ~125Hz, Step: 1/12 OCT
b) Level Range: +3dB ~-12dB, Step: 1dB
c) Q Range: 2.0 / 2.4 / 2.9 / 3.6 / 4.8 / 5.7 / 7.2 / 9.6 / 14.4
E. Auto Room EQ (oponal, incl. mic choice, dedicated ADI Sharc™ DSP, advanced program-ready)
o 3 posion acquision. Each pos. calc. with
12 measurement, 5-band PEQ correcon
F. Input Source:
o Analog or Digital audio source selecon
Advanced Control (for GUI via USB port, PC or Mac)
a) Room auto-EQ GUI gives post-correcon spectrum display, EQ variance/specs
b) I/O level meter (0-99dB)
c) Five-band Parametric EQ Sengs
o EQ types: Peaking, high shelving, low shelving, notch, HPF, LPF
o Frequency range: 20Hz ~200Hz, Step: 1Hz
o Level range: +12dB ~ -6dB, Step: 0.1dB Q range: 0.4 ~11, Step: 0.1
d) LIMITER
o Threshold: -12~0 dB, Step: 0.1dB
o Aack: 0.1 ~100ms, Step: 0.1ms
o Release: 100~5000ms Step: 0.1ms