PHONO PRE-AMPLIFIER
EDIT PARAMS
You can edit parameters in the following order. Rotate the encoder to see the available settings and press to
confirm and move on to the next one
· Cartridge type
· Load resistance
· Capacitance
· Arm wiring
· Equalisation
There are some limitations to prevent DC offset occurring. If a low or medium MC cartridge is selected the load
resistance will be limited to max 1k. For other gain settings, all load resistances are available.
After the last dialogue you will be prompted to save the new settings as a profile. If you choose YES, the name
editing screen will appear. Refer to Editing Profile Names for this information. If you do not choose to save the
parameters as a profile, they will be stored as current settings.
To save the current settings as a profile later, go through the EDIT PARAMS menu again without changing any
settings. While editing the name of a new profile, hold the BACK button for 1 second to cancel creating a new
profile and return to the main menu.
While inside this menu, press BACK to go one step back. If you are on the first dialogue and press BACK, you will
be prompted to cancel the changes.
EDITING PROFILE NAMES
When entering the name use the encoder to scroll through the alphabet from A to Z,
then symbols ! “ # $ % ' ( ) * + , - . /
then digits 0 – 9
then symbols : ; < = > ? .
You can enter a space by rotating the encoder one position anti clockwise from A.
Press the encoder button briefly to enter a symbol. Press BACK to erase a symbol. Hold the encoder for 1 second
to finish editing the name and save it. Hold the BACK button for 1 second to cancel any changes to the name.
EDIT PROFILE
In this menu you can edit the name or parameters of an existing profile. Use the encoder to scroll through the
list of available profiles. Use short click prompts to edit the name; long click prompts to edit the parameters.
Hold the encoder button to edit the chosen parameters. The current name will be displayed and all normal
name editing options are available. Hold the encoder button to confirm the changes. New parameters are
stored in the same profile. Hold the BACK button to cancel all the changes and return to the list of profiles. Note
that if you change the parameters of a profile that is not active, any changes will not become active until you
select that profile.
You can delete a profile by holding the BACK button for one second. You cannot delete a profile that is currently
active. Press the BACK button to return to main menu at any time.
DELETE ALL
This function allows you to erase all profiles and reset current settings to factory defaults. If selected, a message
DELETED will be displayed. No presets will be deleted until you select YES in this dialogue.
Page 3