Carson SC-407 Stereo Amplifier User Manual


 
Page 6 of 12 SC-407-10 Ver. B Installation and Operating Instructions
05/07/05 CP4842C
LIGHT CONTROL CONNECTIONS
In addition to these instructions a label located on the bottom of the unit shows the light control
switch connections.
Fuses / Breakers
The lighting control circuits of this unit are not fused
. Automotive fuses or circuit breakers must
be connected between the power source and the unit properly rated for the circuit requirements.
Failure to install proper circuit breakers or fuses can result in damage to the unit and/or
vehicle.
Lever Switch Connections
The following diagram shows proper connection of the lever switch leads located at the rear.
Note: Negative (NEG) connection must also be made on 10-Pin plug for proper operation.
Recommended
Wire Size
Amps Size
5 - 10 #16
10 - 15 #14
15 - 25 #12
25 - 40 #10
40 - 60 #8
60 - 80 #6
Use next larger size
if longer than 10 ft.
YEL
GRN
BLU
RED
Circuit Breaker
or Fuse
60 AMP Max.
LOAD 1
LOAD 2
LOAD 3
+
BATT
-
Lever
Position
Turns
On
Off All off
1 Load 1 only
2 Loads 1 and 2
3 Loads 1, 2 and 3
Off 1 2 3