Ashly NE800 Stereo Amplifier User Manual


 
ne1600 ne1600.10 ne1600.70
RATED RATED RATED RATED RATED RATED RATED RATED RATED
WATTS VOLTS LOAD
WATTS VOLTS LOAD
WATTS VOLTS LOAD
800 100 12.5 800 70 6.1
450 60 8 512* 64* 8* 613 70 8
800 56.6 4 256* 32* 4* 522* 45.7* 4*
400* 28.3* 2* 128* 16* 2* 261* 22.9* 2*
Stereo Mode
Both Channels Driven
20Hz - 20KHz 1% THD
Bridged Mode
ne1600 Models
ne2400 ne2400.10
RATED RATED RATED RATED RATED RATED
WATTS VOLTS LOAD
WATTS VOLTS LOAD
1200 100 8.3
700 74.8 8 1152* 96* 8*
1200 69.3 4 576* 48* 4*
600* 34.6* 2* 288* 24* 2*
1600 113 8 1600 200 25 1600 140 12.3
Stereo Mode
Both Channels Driven
20Hz - 20KHz 1% THD
Bridged Mode
ne2400 Models
All NE two channel power amplifiers come standard with XLR and Euroblock input connectors, and Speakon/
Euroblock output connectors. All models include balanced analog inputs, bridge mono mode, an 80Hz hi-pass filter,
input sensitivity switch, full Ethernet control using Protea
ne
software, remote standby for power up, and DC remote
level control using an Ashly WR-1 or equivalent.
All NE two channel amplifiers also include Analog Aux Outputs on XLR and Euroblock connectors. The Aux
Outputs are buffered signals taken just before the power amplifier driver stage. If there is no DSP capability installed in
the amplifier, the Aux Outputs are simply a buffered signal matching the inputs. If the amplifier has DSP installed
however, each Aux Output can be independently configured, in addition to the two main amplifier channels, with its own
DSP processing and any input source, including AES/EBU or CobraNet (if installed) to drive other power amplifiers.
Additional options are available for the NE
two channel power amplifiers including the following:
1) Internal DSP Processing - With this factory installed option, and using Protea
ne
(network enabled) software,
each amplifier input channel can be configured with pluggable DSP blocks to have its own dynamics control, gain
functions, graphic and/or parametric EQ, Hi-pass/Lo-pass filters, time delay, metering, and test signal generator. A
mixer section with assignable routing allows any input to drive any or all amplifier outputs. Outputs have the same DSP
functions as inputs, with the addition of a fast, automated crossover setup. Both inputs and outputs can copy/paste their
settings to other channels, or can link with one or more other channels to track their settings.
Presets can be used to store and retrieve global parameters of an amplifier’s control surface and DSP section from
a file. In addition, Sub Presets allow for a collection of individual DSP function parameters within and across both
channels of an amplifier to be stored and recalled as a set, affecting only those parameters which have been tagged. Up
to 35 presets/subpresets can be stored within the amplifier, and can be recalled in real time via Ethernet from a computer
using Protea
ne
software.
2) AES/EBU Input - Using an optional input card, NE
two channel amplifiers can accept AES/EBU digital inputs.
This protocol allows 2 channels of digital audio to be transmitted over a single cable, thus maintaining a completely digital
signal path until just before the power amplification stage. 48kHz & 96kHz data rates are supported.
3) Network Digital Audio (CobraNet) - This option allows the NE two channel amplifier to be part of a net-
worked audio distribution system. CobraNet is a technology developed and supported by Cirrus Logic (www.cirrus.com).
It is a combination of software, hardware and network protocol which allows distribution of multiple channels of real-
time, high quality digital audio over a standard Ethernet Network. For detailed information about CobraNet or its
implementation visit www.cobranet.info.
2400 139 8 2400 200 16.7
* Values indicated by an asterisk are intended as guidelines only. Amplifier is not rated for this load impedance
and may self-protect depending on load and program.
Operating Manual - NE Two Channel Power Amplifiers