Altinex MT108-103 Stereo Amplifier User Manual


 
MULTITASKER
400-0162-003
15
7.3. SUMMARY OF COMMANDS
Basic Commands
1) [VER] Display firmware version
2) [C] Display card status
3) [CnS] Save card settings
4) [CLR] Reset card to defaults
5) [TEST] Test internal memory ICs
6) [HELP] Display available commands
Feedback Commands
7) [FBD] Feedback delay on/off
8) [?] Display system cards
9) [?C] Display card information
10) [STA1] Auto-feedback on
11) [STA0] Auto-feedback off
12) [...F] Display OK after command
Card Control Commands
13) […S] Save command being sent
14) [ONm] Turn on output
15) [OFFm] Turn off output
16) […P] Sets the path, [SW] preload
17) [SW] Switch preloaded outputs
ID Commands
18) [RSI] Reset Card IDs to defaults
19) [SIDn] Set all Card IDs
20) [SIDnCi] Set one Card ID
21) [SID+] Set all Card IDs to an offset
22) [RSN] Display card slot number
Group Commands
23) [WR] Add card(s) to a group
24) [RMC] Remove card(s) from group
25) [RMG] Delete group
26) [RD] Display group members
TROUBLESHOOTING GUIDE 8
We have carefully tested and found no problems in
the supplied MT108-103; however, we would like to
offer suggestions for the following:
8.1 LED IS NOT LIT
Cause 1: Card cage is not plugged in.
Solution: Make sure the enclosure is powered
and has AC power turned on. If the
LED is still not on, see Cause 2.
Cause 2: Card is not plugged in all the way.
Solution: Push the card in all the way. If the
LED is still not on, see Cause 3.
Cause 3: Card cage slot has a problem.
Solution 1: Test the card in other slots of the
card cage. If the slot is damaged,
the card may work in other slots. If
other slots work, and the LED lights,
the problem is the card cage slot.
The card cage may require service.
Call ALTINEX at (714) 990-2300. If
the other slots do not work and the
LED is still not on, see Solution 2.
Solution 2: Take any other known good card
with an LED and verify that the slot
used is good by seeing if the other
card’s LED lights in that slot. If it
lights, then the original card may be
the source of the problem. Call
ALTINEX at (714) 990-2300.
8.2 NO SOUND
Cause 1: The source has a problem.
Solution: Check the source and make sure
that it is working at an appropriate
volume level and all source
connections are correct. If the
source is working and there is still
no sound, see Cause 2.