Ui = Unit ID (i = # from 0 to 9) (refer to the
MT100-100 user’s guide for explanation)
Example:
If one MT108-103 card is plugged in slot #2 of
unit 3: Sending the command [VERC2U3], will
yield the following feedback from the
Multi-Tasker™
MT108-103 690-0127-007
MT108-103 = card type
690-0127-007 = software version
2. [C]
This command receives the status of the card.
Command Format: [CnUi]
Cn = card id (n = from 1 to 19)
Ui = unit id (i = from 0 to 9) (refer to the
MT100-100 user’s guide for explanation)
Example:
If one MT108-103 card is plugged into slot #2 of
unit 3 with outputs 1 and 2 ON, sending the
command [C2U3] will yield the following
feedback:
ON: 1,2 C02
If there is no card plugged in slot #2 of unit 3,
the Multi-Tasker™ will not return any feedback.
3. [CiS]
This command saves the current status of the
card's output enable configuration. This
configuration will be restored after system is
reset or powered off then on.
Ci = card number
S = save configuration
If Inputs 1,2,3 and 4 are enabled, the feedback
after sending the command [C4S], for slot 4,
would be:
ON:1,2,3,4 C04 Saved
4. [SIG]
The Signal Present command tests for the
presence of a signal on the input. After sending
the command, the feedback will be either "1"
signifying a signal is present, or a "0" indicating
no signal was detected.
Command Format: [SIGCnUi]
Cn = card number
Ui = unit ID
Example:
To check for the presence of an input signal on
card 4, send the command [SIGC4] and verify
feedback of "1" or "0".
5. [ON]
This command enables one or more outputs of
a single card or a group of cards.
[ONmCnUi]: for a single card
This command enables output “m” without
affecting any other outputs.
m = Output number (m = 1 to 4)
n = Card ID number (n = 1 to 19)
i = Unit ID number (i = 0 to 9)
Example:
1) [ON12C5U3]: Turns ON only outputs 1
and 2 of the MT108-103 card located in slot
#5 of the MT100-100 Enclosure with unit
ID3.
2) [ON3C5U3]: Turns ON only output 3 of the
MT108-103 card located in slot #5 of the
MT100-100 Enclosure with unit ID3. After
the [ON12C5U3] and [ON3C5U3]
commands have been executed, outputs 1,
2 and 3 will be ON.
3) [ONC5U3]: Turns ON all outputs of the
card. This is the equivalent of sending the
command [ON1234C5U3].
[ONmGkUi]: for a group of cards
This command enables output "m" for each card
in group "k" of unit "i".
m = card output (m = # from 1-4)
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)