7. Install tray support (if supplied) after oven
is installed onto stand. Use the four knurled
screws to secure the support to the legs.
FRONT
Figure 4: Assembled
Combination Oven Stand
LOCATION
Allow space for operating the oven. Do not
obstruct the ventilation port above the oven.
To provide ventilation access, allow 1" of
clearance on the left side of the oven and 2
1
/2"
clearance on the rear side of the oven. A
minimum of 18" must be provided on the right
side of the oven for operation, cleaning and
service. An optional heat shield assembly is
required if the clearance is less than 18" on
the right side of the oven.
LEVELING
Position the oven in its final installed location.
Place a level on the horizontal area of the
cabinet. Adjust the feet to level the oven in
both the left-to-right and front-to-rear
directions.
ELECTRICAL SPECIFICATIONS
The data plate is located on the front lower
right side of the oven.
Model Voltage Amperage Kilowatts Phase
CEM6U 208 26 9.4 3
CEM6U 240 25 10.3 3
CEM6U 480 11 9.4 3
CEM10U 208 43 15.5 3
CEM10U 240 40 16.8 3
CEM10U 480 19 15.5 3
CEM20U 208 54 19.5 3
CEM20U 240 48 24.0 3
CEM20U 480 27 22.1 3
Electrical Specifications Chart