RLC-PRC006-EN6
Simple Installation
• Compact Physical Size. The Trane
Model RTAC chiller averages a 20%
reduction in physical footprint, while
the greatest change is actually 40%
smaller when compared against the
previous design. This improvement
makes the RTAC the smallest air-cooled
chiller in the industry and a prime
candidate for installations that have
space constraints. All physical sizes
were changed without sacrificing the
side clearances needed to supply fresh
airflow without coil starvation.
• Close Spacing Installation. The air-
cooled Series R
™
Chiller has the tightest
recommended side clearance in the
industry, four feet for maximum
performance. In situations where
equipment must be installed with less
clearance than recommended, which
frequently occurs in retrofit
applications, restricted airflow is
common. Conventional chillers may
not work at all. However, the air-cooled
Series R chiller with Adaptive Control
™
microprocessor will make as much
chilled water as possible given the
actual installed conditions, stay on line
during unforeseen abnormal
conditions, and optimize the unit
performance. Consult your Trane sales
engineer for more details.
• Factory Testing Means Trouble-Free
Start-Up. All air-cooled Series R chillers
are given a complete functional test at
the factory. This computer-based test
program completely checks the
sensors, wiring, electrical components,
microprocessor function,
communication capability, expansion
valve performance and fans. In
addition, each compressor is run and
tested to verify capacity and efficiency.
Where applicable, each unit is factory
preset to the customer’s design
conditions; an example would be
leaving liquid temperature setpoint.
The result of this test program is that
the chiller arrives at the job site fully
tested and ready for operation.
• Factory Installed and Tested Controls/
Options Speed Installation. All Series R
chiller options, including main power
supply disconnect, low ambient
control, ambient temperature sensor,
low ambient lockout, communication
interface and ice making controls, are
factory installed and tested. Some
manufacturers send accessories in
pieces to be field installed. With Trane,
the customer saves on installation
expense and has assurance that ALL
chiller controls/options have been
tested and will function as intended.
Features and
Benefits
Superior Control
The Adaptive Control
™
microprocessor
system enhances the air-cooled Series R
chiller by providing the very latest chiller
control technology. With the Adaptive
Control microprocessor, unnecessary
service calls and unhappy tenants are
avoided. The unit is designed not to trip
or unnecessarily shut down. Only when
the Tracer
™
chiller controllers have
exhausted all possible corrective actions
and the unit is still violating an operating
limit will the chiller shut down. Controls
on other equipment typically shut down
the chiller, usually just when it is needed
the most.
For example:
A typical five-year-old chiller with dirty
coils might trip-out on high pressure
cutout on a 100°F [38°C] day in August. A
hot day is just when comfort cooling is
needed the most. In contrast, the air-
cooled Series R chiller with an Adaptive
Control microprocessor will stage fans
on, modulate electronic expansion valve,
and modulate slide valve position as it
approaches a high pressure cutout,
thereby keeping the chiller on-line when