A SERVICE OF

logo

10
Control
XCD-V50CR
XCD-V50
With the exception of bits 8 to 15 of the 400h offset
address field, the length of the entire ConfigROM is
made up of 21h Quadlets. So the ConfigROM from
400h to 487h is 136 bytes.
For offset address 424h, the length of the
UnitDirectory is 3 Quadlets. UnitSpecID (00A02Dh)
conforms to 1394TA standards. UnitSoftwareVersion
(000102h) conforms to IIDC Standards, Version 1.3X.
The offset address of UnitDependentInfo is required to
be
430h + 000001h * 4 = 434h
Offset 0-7 8-15 16-23 24-31
Bus 400h 04 21 ROM CRC
Info 404h 31 33 39 34
Block 408h 20 FF 60 00
40ch 08 00 46 02 NodeVendorID/ChipID-Hi
410h 00 10 00 01 ChipID-Lo
Root 414h 0003 CRC
Directory 418h 03 08 00 46 ModuleVendorID
41ch 0C 00 83 C0
420h D1 00 00 01 UnitDirectoryOffset
Offset 0-7 8-15 16-23 24-31
Unit 424h 0003 CRC
Directory 428h 12 00 A0 2D UnitSpecID
42Ch 13 00 01 02 UnitSoftwareVersion
430h D4 00 00 01 UnitDependentDirectory Offset
ConfigROM
The UnitDirectory offset address is required to be
420h +000004h * 1 = 424h