![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/87/f87143dc-c5d0-4911-b1c4-642af4814e61/f87143dc-c5d0-4911-b1c4-642af4814e61-bg20.png)
Chapter 3 Preparations
32
3-1 Connections and Settings
recording from the RM-280 (when XDCAM mode is
selected).
RM-280 settings
EDITOR/REMOTE CONTROL switch: REMOTE
CONTROL
Setup menu item 19 “FNC MODE”: XDCAM
For information about function assignments to PF keys in
XDCAM mode, refer to the Operation Manual for the RM-
280.
PDW-R1 settings
Remote control switch (see page 12): REMOTE
Extended menu item 214 “REMOTE INTERFACE”:
9PIN
3-1-7 Editing Control Unit Settings
When connecting an editing control unit to use with this
unit, make the following settings, depending on the editing
control unit model.
BVE-600/700/900/910/2000/9100
Set VTR constants as follows.
FXE-100/120
Set VTR constants as follows.
RM-450
Set the DIP switches as follows.
• Left switch
• Right switch
PVE-500
No settings required.
Line
mode
VTR CONSTANT 1
12345678
525/60 A0 92 00 96 05 05 03 80
625/50 A1 92 00 7D 05 05 03 80
Line
mode
VTR CONSTANT 2
12345678
525/60 0A 07 FE 00 80 5A FF 5A
625/50 0A 07 FE 00 80 4C FF 4B
Line
mode
12345678
525/60 A0 92 00 96 05 05 03 80
625/50 A1 92 00 7D 05 05 03 80
Line
mode
9 101112131415
525/60 0A 07 FE 00 80 5A FF
625/50 0A 07 FE 00 80 4C FF
Line
mode
76543210
525/60OFF––OFF––––
625/50OFF––OFF––––
Line
mode
76543210
525/60 OFF– OFFON OFFOFFON ON
625/50 ON – OFF ON OFF OFF ON ON