56 C307M-I (11/05)
APPENDIX
NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the
DIP switches settings have no effect on Coaxitron control signals.
*SW1-3 is not used; set it in the OFF position.
*SW1-4 is not used; set it in the OFF position.
Table A. Switch Settings for SW1
Baud Rate Switch Setting
SW1-1 SW1-2 SW1-3
2400 OFF OFF OFF*
4800 ON OFF OFF*
9600 OFF ON OFF*
Switch Setting
SW1-4 SW1-5 SW1-6 SW1-7 SW1-8
OFF* Note (1) Note (2) Note (3) Note (4)
NOTES:
(1) SW1-5 OFF - For controllers that have more than 32 presets.
ON - For American Dynamics controllers (32 presets).
(2) SW1-6 OFF - For all control systems except CM9502 with variable speed
keyboards. For CM9502 with fixed speed keyboards, set
switch OFF.
ON - For CM9502 with variable speed keyboards to get smoother
joystick control.
(3) SW1-7 OFF - RS-422 transmitter is not terminated.
ON - RS-422 transmitter is terminated.
(4) SW1-8 OFF - 1.2 volt peak-to-peak video level.