![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/f6/cf618afd-6857-434a-9bfa-8a94527767bd/cf618afd-6857-434a-9bfa-8a94527767bd-bg28.png)
Appendix B: Demo Kit Wiring
40
Intelli-M Hardware Installation And Reference Guide
Controller Configuration:
• Description: S-EIDC-U 300
• IP Address: 169.254.1.1
• Serial #: Obtain from back of S-EIDC-U
• Reader Type:
• IN: Card reader
• OUT: Reader + keypad
Access Service Configuration:
• General Tab:
• Description: Basic Door
• Controller: S-EIDC-U (local default - 1.300)
• Lock Schedule: Default (1/0/0/0)
• Unlock Mode: Default Pulse (4 sec)
• Door Open Too Long: Default
• Anti-Passback: Default
• Inputs Tab:
• Input 1 – Door Contact (Enable Door Status)
• Outputs Tab:
• Lock Outputs:
• Output 1 – Door Strike
• Output 3 – Door Status LED
• Warning Outputs:
• Output 4 – Buzzer
• Triggers Tab:
• Triggers:
• CR-IN – Reader
• CR-OUT – Reader + keypad
• Input 2 - REX
Alarm Service Configuration:
• General Tab
• Controller: S-EIDC-U (local default - 1.300)
• Input: Input 1 – Door Contact
• Output: Output 2 – Alarm LED
• Conditions: Input 3 – REX Free Egress