OM-494 Page 29
SECTION 6 − OPERATING THE WELDING GENERATOR
When facing the front panel, the Welder B controls and weld terminals are on the
right and the Welder A side controls and weld terminals are on the left.
NOTE
6-1. Engine Controls
. See Section 6-3 for weld control
descriptions.
1 Engine Start Button
2 Manual Stop Control
3 Ether Starting Aid Switch (Optional)
Push switch up and release while cranking
engine to release ether.
To Start: Press button and use Ether switch
(if necessary). Release button when engine
starts.
. If the engine does not start, let engine
come to a complete stop before attempt-
ing restart.
To Stop: Pull control out and hold. Release
control when engine stops.
4 Battery Charging Warning Light
Light goes on when battery is not charging.
Y If light goes on, stop engine and check
engine belt.
5 Engine Hour Meter
190 377