OM-223 037 Page 27
5-9. Connecting To Remote 14 Receptacle RC14
Socket* Socket Information
24 VOLTS AC
A 24 volts ac. Protected by sup-
plementary protector CB8.
B Contact closure to A completes
24 volt ac contactor control
circuit.
C Output to remote control:+10
volts dc in MIG mode; 0 to +10
volts dc in Stick or TIG mode.
REMOTE
D Remote control circuit common.
CONTROL
E DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
OR
F
Current feedback: 1 volt per
100 amperes.
H Voltage feedback: 1 volt per 10
arc volts.
GND
K Chassis common.
Ref 804 068
* The remaining sockets are not used.
NEUTRAL G Circuit common for 24 volt ac
circuit.
5-10. Gas Connections
804 068
1 Gas Fitting
Fittings have 5/8-18 right-hand
threads.
2 Cylinder Valve
Open valve slightly to blow dirt from
valve. Close valve.
3 Regulator/Flowmeter
4 Flow Adjust
Typical flow rate is 15 cfh (cubic feet
per hour).
Connect gas hose between regula-
tor/flowmeter and gas fitting on front
of unit.
Tools Needed:
3
2
4
1
5/8, 1-1/8 in