A SERVICE OF

logo

Page 6 of 19 2452-222/2452-422/2452-522 - Rev: 1/21/2014 7:50 AM
Local Control Operations
DIN Rail’s switch operation mode affects how it responds to commands; so it’s important to properly program DIN
Rail for the correct type of switch you are installing. DIN Rail on/off buttons function exactly like the top and bottom of
your wall switch.
Note: LED will blink red for a few seconds if one or more responders do not acknowledge a message.
Latching Wall Switch (Default)
Single Momentary Wall Switch
Dual Momentary Wall Switch
Adjust Local Settings
Local On-Level
Local on-level is the brightness that the load wired into DIN Rail will come on when turned on at the DIN Rail paddle.
The default local on-level is 100% brightness, but it can be set to any one of 32 fixed brightness levels (3% to 100%).
If you want DIN Rail to turn the load on at its last brightness level (prior to being turned off), see Resume Dim
.
1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
Connected load/responders
Latching switch
Tap
LED
Top
On
(ramped)
Green
Bottom
Off
(ramped)
Red
Connected load/responders
Single momentary switch
Tap
Press and hold
Double-tap
LED
Switch
On/Off
(ramped)
Brighten/Dim
(until release or full-
on/off)
On/Off
(instant)
Green/
Red
Connected load/responders
Dual momentary switch
Tap
Press and hold
Double-tap
LED
Top
On
(ramped)
Brighten
(until release or 100%)
On
(instant)
Green
Bottom
Off
(ramped)
Dim
(until release or off)
Off
(instant)
Red