Page 11 of 19 2452-222/2452-422/2452-522 - Rev: 1/21/2014 7:50 AM
2) Press and hold DIN Rail set button until it beeps a second time
DIN Rail LED will start blinking red
3) Tap DIN Rail set button
DIN Rail LED will start double-blinking red
4) For each responder you are removing, press and hold responder set button until it double-beeps
5) Tap On, Off or the Set button once to exit Multi-Unlink
DIN Rail LED will stop blinking
6) Test by tapping DIN Rail on and off
None of the former responders will respond
Factory Reset
All settings and scenes will be erased and return to factory default settings.
1) Remove scene memberships from all controllers, otherwise controllers will retry commands repetitively, creating
network delays (see Remove DIN Rail as a Responder (Unlink)
2) Press and hold DIN Rail set button until it beeps
LED will start blinking green
3) Press and hold DIN Rail set button until it beeps a second time
LED will start blinking red
4) Press and hold DIN Rail set button until it beeps a third time
LED will start blinking green
5) Slowly tap set DIN Rail button 3 times
LED will start double-blinking green
6) Press and hold DIN Rail set button (and don’t let go)
DIN Rail will begin a long beep
7) Release DIN Rail set button after beeping has stopped
After a few seconds DIN Rail will double-beep
DIN Rail will turn on and LED will turn green
X10 Setup
DIN Rail ships with no X10 address assigned.
Assign an X10 Address
1) Press and hold DIN Rail set button until it beeps
DIN Rail LED will start blinking green
2) Send the X10 address 3 times (with or without commands)
Example: A1-A1-A1-AON or A1-AON-A1-AON-A1-AON
DIN Rail will double-beep and its LED will stop blinking
3) Test by sending X10 on and off commands
Load will turn on and off
Remove X10 Address
1) Press and hold DIN Rail set button until it beeps
DIN Rail LED will start blinking green
2) Press and hold DIN Rail set button until it beeps a second time
DIN Rail LED will start blinking red
3) Send the X10 address 3 times (with or without commands)
DIN Rail will double-beep and its LED will stop blinking
4) Test by sending X10 on and off commands
Load will not respond