A SERVICE OF

logo

Page 16 of 19 2452-222/2452-422/2452-522 - Rev: 1/21/2014 7:50 AM
DIN Rail, it takes a long
time for other INSTEON
devices it is controlling to
respond
scene responder that is not
powered on
If the INSTEON device is still available, remove it from
DIN Rail and then re-add it
Perform a factory reset
The load is buzzing when
on or dim
The dimming component
inside DIN Rail "chops" the
power line sine wave to
reduce the power
The bulb filaments are vibrating. Use rough-service or
appliance grade bulbs to reduce the noise
Run DIN Rail in the "full-on" mode or switch to a non-
dimming DIN Rail On/Off (Relay) Switch
DIN Rail is locked up
A surge or excessive noise
on the power line occurred
Power cycle the device
Perform a factory reset
DIN Rail is getting warm
to the touch
It is normal for wall dimmers
to get warm (DIN Rail
conforms to Safety
standards)
DIN Rail will dissipate about 1 Watt per 100 Watts
controlled. Controlling a smaller load all will help lessen
the heat.
DIN Rail can turn off my
responder, but nothing
happens when I send an
on
Responder scene level is off Add responder to scene again at desired scene on-level
Controller can turn off
DIN
Rail, DIN Rail does not
respond to on
DIN Rail may be added to a
scene at its off state
Add DIN Rail to scene again at desired scene on-level
DIN Rail still controls
devices even after factory
reset
Scene memberships exist in
the responder
Remove responder from DIN Rail scene