For use in country or region: Spare part number: For use in country or region: Spare part number:
For use in Brazil 677713-201 For use in Portugal 677713-131
For use in Canada 677713-121 For use in Romania 677713-271
For use in the Czech Republic
and Slovenia
677713-FL1 For use in Russia 677713-251
For use in Denmark, Finland, and
Norway
677713-DH1 For use in Saudi Arabia 677713-171
For use in France 677713-051 For use in South Korea 677713-AD1
For use in Germany 677713-041 For use in Spain 677713-071
For use in Greece 677713-DJ1 For use in Switzerland 677713-BG1
For use in Hungary 677713-211 For use in Taiwan 677713-AB1
For use in India 677713-D61 For use in Thailand 677713-281
For use in Israel 677713-BB1 For use in Turkey 677713-141
For use in Italy 677713-061 For use in the United Kingdom 677713-031
For use in Japan 677713-291 For use in the United States 677713-001
For use in Latin America 677713-161
Keyboard for use only with Alexandre Herchcovitch Special Edition computer models
For use in Brazil 683100-201 For use in France 683100-121
For use in Latin America 683100-161 For use in the United States 683100-001
Before removing the keyboard, follow these steps:
1. Shut down the computer. If you are unsure whether the computer is off or in Hibernation, turn
the computer on, and then shut it down through the operating system.
2. Disconnect all external devices connected to the computer.
3. Disconnect the power from the computer by first unplugging the power cord from the AC outlet
and then unplugging the AC adapter from the computer.
4. Remove the battery (see
Battery on page 44).
5. Remove the service door (see
WLAN module on page 48).
Remove the keyboard:
1. Remove the two rubber feet (1) that are attached to the rear corner covers. The rubber feet are
attached to the rear corner covers by double-sided tape and are included in the Rubber Kit,
spare part number 664996-001.
2. Remove the two Phillips PM2.0×5.7 screws (2) that secure the rear corner covers to the
computer.
60 Chapter 4 Removal and replacement procedures