9
o If the fan rotates, but is not very fast: Power loss will cause this unit to not function
properly. Try plugging the fan into another outlet that is closer. Change the power
switch on the unit to the faster speed. Does it rotate faster? You need to change to a
heavier (minimum 12 awg) extension cord. Is the power supply dedicated solely to
this unit? Are you sharing power with other equipment? Try disconnecting any other
loads on the same circuit. If the fan rotates faster, then you need a dedicated power
source.
o If you are not getting fluid to the Super Foam Dome
TM
unit: Check pump
separately by disconnecting from the hose and by disconnecting the fan from the
GFCI and turning on the unit for a short time. If pump does not work, check another
power outlet. If it still does not work, replace unit by calling for assistance.
o If the unit was foaming, then stops:
o Check the intake hose of the pump in the bottom of the barrel. Is there sufficient
fluid? Is there dirt in the bottom of the barrel? Keep the barrel clean and
occasionally check to be sure dirt is not getting inside the barrel, as this will clog
the pump. Shut off all power, disconnect the pump from the GFCI and remove the
pump from the barrel. Disconnect the hoses and check for debris or dirt that may
be clogging the unit. Connect the suction hose to the pump and plug in the pump
separately to see the output, catching the output in a bucket. The output should
be open and free.
o Check the nylon tubing going to the Super Foam Dome
TM
unit. Is it crimped or
bent in a 90 degree angle? Change the tubing.
o Check the connection to the Super Foam Dome
TM
unit. There is a screen that will
capture dirt from entering the nozzle. Disconnect the tubing and clean the screen
at the connection. Reconnect and try again.
o If still clogged at the nozzle, remove unit to outside, connect a high pressure hose
to the nozzle connection. While holding the unit in it’s hung position so the water
will run down and out of the unit, (not up or in the unit), turn on the water to
pressurize the nozzle inside and clean the nozzle. You should have plenty of
pressure and volume to remove any clogged item. If still clogged, send the unit
back to be serviced.
o If the modulator appears to yellow or change color: Have you been rinsing the
unit after each use? Dark areas that are warm are easy for bacteria to grow. Rinse
and let the fan blow out the modulator after each use. Never leave the modulator
(sock) wet or dripping with solution.