BLOWER CONVERSION FROM UPFLOW
TO COUNTERFLOW OR HORIZONTAL
RIGHT DISCHARGE
Following the directions on Figure 3 for counterow and
horizontal right discharge, the indoor blower must be
removed and turned over in its mounting conguration.
Step 1 Remove both front service panels from the
GTB1-A.
Step 2 Remove two screws securing blower at top
of GTB1-A (See Figure 3), and slide the
blower forward and out of the chassis.
Step 3 Remove two screws from front ll plate on
bottom of GTB1-A, and slide both pieces of
metal forward and out of chassis.
Step 4 Dip switch #4 on blower tap select control
must be turned “on”. (Refer to Wiring
Diagram 4117-100.)
Step 5 While turning on tap #4 above, adjust the
other taps accordingly for the tonnage of unit
being applied. (Refer to Wiring Diagram
4117-100.)
Step 6 Turn blower over and slide into rails of
bottom rear of the GTB1-A front ll plate
that was removed in Step 3 above.
Step 7 Remove bottom rear ll plate from bottom
front ll plate (discard rear), and resecure
front ll plate into unit base and front of
blower.
Step 8 Replace GTB1-A front service doors after
making line and control voltage wiring
connections.
BLOWER LINE POWER CONNECTION
Power connections for the GTB1-A can be made two
different ways.
The rst is in “stacked” congurations, the blower can
be plugged into an electrical connection from the bottom
of the compressor (GTC**S2 Model Unit). This will
work for either upow or counterow applications. All
electrical sizing has been sized to accommodate this.
The second is with “remote” blower (meaning separate
from the compressor section). Supplied in the GTB1-A
is an adaptor wire harness. On the right-hand side of the
GTB1-A chassis is a ½" electrical knockout. This harness
can be installed through this knockout with the supplied
strain relief into a standard electrical junction box (eld
supplied). Electrical load sizing is included on the serial
plate of the GTB1-A for the required separate branch
circuit (See Figure 4).