9
MZ-E501
2. During each test, press and hold down > N key or .
key for a while to move the optical pickup on the sled outer or
inner perimeter.
3. Each test item is assigned with a three-digit item number. The
100th place is a major item, 10th place is a middle item, and unit
place is a minor item.
Note: In the Power mode, the item title display is only displayed.
5. To terminate the Manual mode and return to the TEST MODE,
press x key.
4-5. OVERALL ADJUSTMENT MODE
4-5-1. Outline of the function
This mode is designed to adjust the servo system automatically by
going through all the adjustment items.
The power adjustment manual setting is performed in this mode also.
Usually, this mode is used to perform automatic adjustments when
servicing the set.
For further information, refer to section 5. ELECTRICAL
ADJUSTMENTS. (See page 12)
4-4. MANUAL MODE
4-4-1. Outline of the function
The Manual mode is designed to perform adjustments and
operational checks on the set’s operation according to each
individual function.
Usually, no adjustments are made in this mode.
However, the Manual mode is used to clear the memory before
performing automatic adjustments in the Overall Adjustment mode.
4-4-2. How to set the Manual mode
1. Set the TEST MODE and press VOL+ key to set the Manual mode.
Remote control LCD display
4. During each test mode, the display is changed from one to
another each time DISPLAY key is pressed.
• Address & Adjusted Value Display
LCD display
• Jitter Value & Adjusted Value Display
LCD display
• Block Error Value & Adjusted Value Display
LCD display
• ADIP Error Value & Adjusted Value Display
LCD display
• Focus Drive Voltage Value &
Adjusted Value Display
• Item Title Display
LCD display
000 Manual
Change Major
Item
Change Middle
Item
Change Minor
Item
Change Adjustment
Value
Write Adjustment
Value
.
key : 100th place of mode number
increase
VOL
+
VOL
–
VOL
+
VOL
–
key : 100th place of mode number
decrease
key : 10th place of mode number
increase
key : 10th place of mode number
decrease
key : Up
key : Down
key : When adjusted value is changed :
Adjusted value is written.
When adjusted value is not changed :
That item is adjusted automatically.
keykey
x
key
x
> N
key
> N
key : Unit place of mode number
increase
key : Unit place of mode number
decrease
> N
X
VOL
+
VOL
–
011 C68S5E
adress
mode number
adjusted value
011 OFEJ5E
jitter value
mode number
adjusted value
011 063B5E
block error value
mode number
adjusted value
011 072A5E
ADIP error value
mode number
adjusted value
011 LrefPw 5 E
item title
mode number
adjusted value
011 000F5E
forcus drive
voltage value
mode number
adjusted value