Sharp MD-MT88H CD Player User Manual


 
01/4/4 88UK_4.fm
28
Useful Features
-Recording from a Microphone-
Recording from a Microphone (continued)
Sound-actuated recording (Mic Syn-
chronised recording)
About pause function
The unit automatically pauses when the microphone
does not pick up any sound for 3 seconds or more.
(Pause function does not work for approximately 10 sec-
onds after a recording starts.) When the microphone
picks up sound again, recording starts automatically.
Notes:
z
Whilst making a mic recording, do not connect any-
thing to the OPTICAL/LINE IN socket on the portable
MD.
z
To use a microphone, be sure it is a plug-in-power
type microphone.
z
Insert the plug firmly. If you don't, the recording will not
be made properly.
z
Use a microphone with a 3.5 mm (1/8") diameter
stereo mini plug.
z
If the unit starts recording too often from low unwanted
noises, set the microphone input to "MIC SYNC L".
z
Recording sensitivity can be changed whilst recording.
1
Press the REC button.
2
Press the or button to adjust the re-
cording level.
Level meter indicator
3
Press the MODE/CHRG button repeatedly
to select the recording mode (page 20).
4
Press the ENTER/SYNC button to select
the recording sensitivity.
MIC SYNC H : Recording starts when the unit
detects -24 dB or more (the unit
can start recording from quiet
sounds).
MIC SYNC L : Recording starts when the unit
detects -12 dB or more.
5
When a sound, such as person speaking,
is picked up by the microphone, recording
will begin automatically.
- When a plug-in-power type microphone is plugged in,
the portable MD will provide power for the micro-
phone's operation.
- If a different type of microphone is plugged in, it may
not operate properly or it may cause the unit to mal-
function.
Web-site:
www.sharp.co.uk/support
Help Line:
08705 274277 (office hours)