Sennheiser SR 300 IEM G3 Satellite Radio User Manual


 
Putting the transmitter into operation
10
̈ Connect the antenna. You have the following options:
You can connect the supplied rod antenna ƽ to the rear of the transmitter (see
page 9). In this case, insert the two blanking plugs into the holes of the blanking
plate (see diagram on page 9).
You can use the AM 2 antenna front mount kit (optional accessory) and mount the rod
antenna to the blanking plate .
You can use a remote antenna, if necessary in conjunction with the AC 3 antenna
combiner.
̈ Slide the transmitter with the mounted blanking plate into the 19” rack.
̈ Secure the rack mount “ear” and the blanking plate to the 19” rack.
Rack mounting two
transmitters
To mount two transmitters into a rack using the GA 3 rack adapter:
̈ Place the two transmitters side by side upside-down onto a flat surface.
̈ Secure the jointing plate to the transmitters using six recessed head screws (M 3x6).
̈ Secure the rack mount “ears” to the transmitters as described on page 8.
To mount the antennas:
̈ Use remote antennas, if necessary in conjunction with the AC 3 antenna combiner.
For more information, visit the ew G3 product pages at www.sennheiser.com.
To mount the transmitters into the rack:
̈ Slide the transmitters into the 19” rack.
̈ Secure the rack mount “ears” to the 19” rack.