Russound Smart Select Volume Control Speaker System User Manual


 
3.2 Power and Data Connections (Refer to Figure 2)
IMPORTANT: If you are unsure of any of the installation proce-
dures, the products should be installed by a professional custom
installer.
1) Make sure the amplifier or receiver is turned Off, and that the
12 Volt power supply is not plugged in.
2) Use 4 conductor, 2 twisted pair wire with shield and drain to
make power and data connections (Russound Part No.
AW2260AB).
3) Strip 1/4 of insulation from the ends of the power and data
wire that will be connected to the SSVC.
4) Using butt connectors, wire nuts or other wire connectors rated
for this application and the size and type of the wire being
used, make connections to the SSVCs power and data wires as
shown in Figure 2. If several volume controls will be connect-
ed, use Russound EZB-1 and EZB-2 connecting blocks to make
wiring easier. These connecting blocks would be additional to
any connecting blocks used for the amplifier and speaker con-
nections in Figure 1.
NOTE: The EZB-1 and EZB-2 connecting blocks have connectors that are labeled L+, L-, R-, R+. You will need to
make connections to the connecting block using alias names (i.e. 12v=L+, Gnd1=L, Gnd2=R, Data=R+).
5) Connect the Smart Select Power Interrupter to the EZB-1 connecting block as shown in Figure 2. The +V
connection from the Smart Select Power Interrupter should connect to the terminal of the EZB-1 which cor-
responds to the +12V connection of the SSVC. The GND connection from the Smart Select Power Interrupter
should connect to the terminal of the EZB-1 which corresponds to the Gnd1 connection of the SSVCs.
6) To eliminate the risk of damaging one or more components of the Smart Select system, make sure that all
connections are correct and that no wires are shorted .
7) Once all connections are made, install the SSVC in the junction box or plaster ring. Insert carefully to avoid
excessive strain on the connector. Taking the time to feed the excess wire out the back of the junction box will
help you with the final assembly. If a junction box will be used, Russound recommends you use plastic junc-
tion boxes, if possible. This is to help ensure that the volume control does not short against the surface of a
metal junction box during installation or removal. The junction box must also have a depth of at least 3 1/8.
4. Ultra-Match Configuration Instructions
With a few simple calculations, Russound Ultra-Match Volume Controls eliminate the need for a speaker
selector. By determining the impedance of the system, the correct jumper settings for the volume controls can be
calculated to allow safe operation of your system.
1) Determine the minimum impedance capability of the amplifier. Normally, this information can be found near
the speaker output terminals on the back of the amplifier (look for a measurement in OHMS).
WRITE THE AMPLIFIERS MINIMUM IMPEDANCE HERE:__________
2) Determine the impedance of your speakers. Most speakers have this information printed on the back near the
speaker terminals. Most speakers are 4 Ohm or 8 Ohm.
WRITE THE SPEAKERS IMPEDANCE HERE:__________
** If you are using speakers of different impedances, you need to determine the average or common impedance.
For example, a pair of 4 ohm speakers can be considered 2 pairs of 8 ohm speakers.
3) Count the number of speaker pairs you intend to connect to the amplifier.
WRITE THE NUMBER OF SPEAKER PAIRS HERE:___________
Now that you have determined all this information you can calculate the settings on the Ultra-Match Volume
Control. The Ultra-Match Volume Controls have jumper settings on one side of the circuit board. The jumpers
have settings for 2x, 4x, 8x. These settings are multipliers and must be set according to the number of speaker
RRLL+R+RLL+
OUTPUT INPUT
SPEAKERS SPEAKERS
SPEAKERS
INPUT
SPEAKERS
12V+(RED)
GND1(BLACK)
GND2(BLACK)
DATA
(YELLOW)
Smart Select
4 conductor,
22AWG 2 twisted
pair wire with sheild
To speakers
and connecting
block (figure 1)
12V 1000mA
power supply
pt. No. 846XP
Smart Select
Volume Control
EZB-1, 4-Way
Connecting
Block
Figure 2
To other Smart
Select
Volume
Controls
3