Russound CAV6.6 Stereo Amplifier User Manual


 
54
INSTALLER
INSTALLATION MENU
Numeric IR (cont’d)
a. Selected: Learned IR Choose Learned IR if the pre-programmed IR code library does
(LrnIR) not support the source component.
i. LEARNED SRC – Select the learned source bank to be assigned to the source
(LnSrc) component. Procedure advances to KEY FUNCTION (step 8)
b. Selected: Unassigned The numeric IR Prefix command is cleared. Procedure advances
(Unasg) to SUFFIX CMD (step 9)
c. Selected: Default Default selects the same device type and device code previously
(Deflt) setup in BASIC SETUP. Procedure advances to KEY FUNCTION
(step 8)
d. Selected: Macro: (To build macros, see Macro Editor page 60)
i. MACRO - Macro loads a series of commands which are processed when
(Macro) activated.
ii. MACRO ID Enter the macro ID number. Menu advances to SUFFIX CMD (step 9)
(MacID)
e. All Other Selections: Procedure advances to DEVICE CODE (step 7)
7. DEVICE CODE Source component code for IR control.
(DevCd)
8. KEY FUNCTION Select a function (Disc, etc.).
(KeyFn)
9. SUFFIX CMD Tells the system whether a command will be issued after the
(Sufix) selection of the numerical value (e.g., 1, 2
Enter
). If “no,” proce-
dure advances to SAVE CHANGES (step 13)
10. COMMAND TYPE Select the type of source command (e.g., CD, TV, etc.).
(CmdTp)
a. Selected: Learned IR Choose Learned IR if the pre-programmed IR code library does
(LrnIR) not support the source component.
i. LEARNED SRC – Select the learned source bank to be assigned to the source
(LnSrc) component. Procedure advances to KEY FUNCTION (step 12)
b. Selected: Unassigned The numeric IR Suffix command is cleared. Procedure advances
(Unasg) to SOURCE NUM (step 1)
c. Selected: Default Default selects the same device type and device code previously
(Deflt) setup in BASIC SETUP. Procedure advances to KEY FUNCTION
(step 12)
d. Selected: Macro: (To build macros, see Macro Editor page 60)