Runco LS-3 Home Theater System User Manual


 
Controls and Functions
Runco LS-3/LS-5 Installation/Operation Manual 5
PRE
L
IMINAR
Y
2.1
LS-3/LS-5 at a Glance
Figure 2-1 and Figure 2-2 show the key LS-3/LS-5 components.
Figure 2-1. LS-3/LS-5 Front/Side View
TOP IR SENSOR
Receives infrared signals from the remote control unit.
POWER BUTTON/STATUS LED
Indicates projector status as follows:
Solid green = AC power present, ready to turn on (lamp not lit)
Flashing green = lamp is warming up or cooling down; keypad functions not allowed
Off = Lamp lit, projector functioning normally
Alternating green/red = Lamp problem (door open, unable to strike, end of life), user
intervention likely to fix problem
Flashing red = Over temperature, user intervention (clear vents, turn on AC) may fix
problem
Solid red = Error that requires servicing (fan fail, Power-on self-test fail etc.)
EXHAUST VENT
Warm air exits the projector through this vent. Ensure that it is not blocked.
FOCUS RING
Rotate this to focus the projected image.
PROJECTION LENS
Available in two versions: standard throw range (1.85:1 to 2.40:1) and short throw
range (1.56:1 to 1.86:1).
2. Controls and Functions
System
Keypad
Intake
Vent
Front
IR Sensor
Top IR Sensor
Power Button/
Status LED
Exhaust Vent
(on side)
Focus Ring
Projection Lens
Zoom Ring