QSC Audio DSP 322UA Stereo System User Manual


 
12
LED Indicators (continued)
QSControl Status (Port) Indicators- There are three LEDs on the front and rear panels labeled RX, TX and LINK. These indicate
the status for the QSControl.net network. Their functions are described below.
RX (receive)- This indicator illuminates any time the DSP 322ua receives data from the network.
TX (transmit)- This indicator illuminates whenever the DSP 322ua transmits data onto the network.
LINK STATUS- The corresponding indicator illuminates when the DSP 322ua is connected to an operating network.
SIGNAL indicators- These indicators will illuminate green for input signals -40dB to -10dB below full scale; yellow for signals
between -10dB to -2dB below full scale; red for -2dB to full scale (or clip).
LCD Display and Controls
The DSP 322ua has a 2 line X 16 character LCD display. The display and the multi-function push-button switches on either side pro-
vide data access and editing capability. The push-button switches on either side of the display are used to navigate through the
menus. The rotary select/accept knob is active for many displayed items allowing you to scroll through choices by rotating the con-
trol, and accepting choices (entering) by pushing in on the control.
The accessible menus and sub menus may appear differently than the example shown. Software updates may occasionally
improve the interface. The basic navigation flow for the DSP 322ua menu system is shown on the following page.
Front Panel Password Lockout
The password lockout provides the ability to restrict access to all of the editable parameters available on the LCD front panel. This
feature is enabled or disabled via QSControl.net software only (refer to the “General Tab” area and click on the “Front Panel Pass-
word” button). When the lockout feature is enabled, all front panel LCD functions are readable, but editing of parameters is now
password protected. While in this mode, any attempt to edit a parameter requires the user to enter the Front Panel Password. The
default factory password is “qsc”. The password is stored in the DSP unit and can be changed using the QSControl.net software.
Once the password has been correctly entered, the DSP will allow edits to the parameters.
After 5 minutes of inactivity, the DSP will automatically reset the Front Panel Password lockout. Re-entry of the password will be
required to resume editing.
The lockout mode can be deliberately disabled via the “Disable Edits” checkbox in the Front Panel Password menu of the QSCon-
trol.net software.