POWER WIRE SIZE
A minimum of 8 gauge or a maximum of 4 gauge wire is
recommended dependent on the application.
The ground wire must be the same gauge as the power wire.
POWER LOCK CONNECTORS
Once you have run both the power and ground wires, then connect
the cables to the amplifier. Cut off excess wire, and using wire
strippers, strip the ends of the power and ground cables
approximately 1/4 inch. Locate the
PowerLock
TM
power and ground
connector (supplied). With a small flat blade screwdriver, loosen the
screws before attempting to insert the cable wires. Insert the wires
into the appropriate hole, and tighten the screws. Once the wires are
secure, the
PowerLock
TM
may be plugged into the amplifier. The
Power/Ground
PowerLock
TM
will accommodate 6 gauge wire for the
DCX 300.2
and
DCX 600.4
, and 4 gauge wire for the
DCX 800.5
and
DCX 1000.4
.
AMPLIFIER BRIDGING
Pairs of channels in
DCX
multi-channel amplifiers are capable of
being bridged into a 4 ohm mono output without switches or bridging
11