Pioneer MJ-L77 CD Player User Manual


 
46
En
Understanding Error Messages
Message
NO DISC
DISC ER *
?DISC
DISC FULL
BLANK DISC
Playback MD
PROTECTED
TOC FULL
Can't REC
TEMP OVER
Can't EDIT
NAME FULL
DEFECT
MECHA ER*
Can't COPY
NOT AUDIO
UTOC ER W
UTOC ER*
DIN UNLOCK
TOC ERR*
SIO ERROR
Description
MD is not loaded.
The MD data cannot be read.
The disc is damaged.
The MD does not contain the TOC or the data is corrupted.
The data is corrupted or the MD is out of standard.
The MD has no space available for recording.
The MD does not contain any recorded information
(including disc name information).
An attempt is made to record or edit a playback-only MD.
The MD is protected against accidental erasure.
The disc does not have the space for recording the track
number and character data (including disc/track names).
Recording cannot be completed successfully due to shock
or disc damage.
The temperature is too high.
Editing is not possible.
There is no space left for registering a disc/track name.
Recording interrupted due to disc damage.
The MD recorder is not functioning properly.
An attempt is made to record copy-prohibited material.
The disc contains non-audio data.
The UTOC data cannot be written properly due to physical
shock or disc damage.
The recorded UTOC data is not conforming to the MD
standard or is otherwise illegible.
The signal at the digital input is not recognized by the
recorder.
The disc is scratched or otherwise damaged.
The TOC data cannot be read.
The MD is out of standard.
Internal communication in the unit has broken down.
Action
Load an MD.
Reload the MD.
Reload the MD.
Use another MD.
Use another MD.
Use another recordable MD.
The disc is ready to be recorded on.
Use a recordable MD.
Release the accidental erasure protection.
Use another recordable MD.
Restart recording or use another MD.
Turn power off and leave to cool.
Retry at another position on the disc.
Shorten the disc/track name.
Use another recordable MD.
Turn power off then on again.
Use a copy-permitted source (an ordinary
CD, etc.).
Record via the analog input.
Use another track.
Use another MD.
Turn power off and on again, then retry
UTOC writing. Do not to expose the unit to
any physical shock during UTOC writing.
Use another MD.
Use the all erase function and record the
MD from the beginning.
Check the connections, and the out-put
mode of the source component.
Use another MD.
Turn power off then on again.
Note: Error messages marked with an asterisk are followed by a number or other symbol.