Power Amplifier f. Pressure-/Flow Valves
Series EC106Installation Manual
IA EC106 UK.INDD RH 02.06
3
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Design
Series
Module Type
Amplifier,
switchable,
pressure-/flow
valves, Ramps
Electronic Module
for Pressure-/ Flow
Valves
DSA, DWE, DWU
RE*W, TDA*LAF,
TEA*LAF
Number of
Channels
Electronic module for the control of proportional
pressure or flow valves. The pressure-/ flow values
are given by externally supplied command signals
and internal ramp potentiometers.
Features
• Processing and amplification of externally sup-
plied positive commands into output signals for
the control solenoid.
• Up to 6 independent channels for the control of
up to 6 valves.
• Each channel is equipped with a slide switch for
selection of pressure or flow valve operation.
• Ramp function
• Pulsed low loss amplifier power stages with
supporting constant current control for constant,
temperature independent solenoid forces.
• Dither generator with applied frequency to
improve static characteristics.
Ordering Code
Design 2 channels 4 channels 6 channels
Supply voltage
[V]
24 ±10%
Power consumption max.
[VA]
70 125 190
Command voltage
[VDC]
0...+10
Reference output
[VDC]
10 ±5% / max. 100mA
Solenoid output current, max.
[A]
2 x 1.3 4 x 1.3 6 x 1.3
Ramps
[s]
0.01...10
Ambient temperature
[°C]
0...+70
Connection 48pole male connector, DIN 41612F
Cable connection Supply connections + valve: AWG15; command inputs AWG20
Fuse DIN 41571 4A medium lag 6.3A medium lag 10A medium lag
Characteristics
EC 106
Code Quantity
02 2
04 4
06 6