V. Connecting the EZ Port to the Essentia amplifier
When the EZ Port is installed in the wall the only part visible
should be the faceplate, speaker connections for zones 1-6, and
a single RJ45 jack. The speaker connections are made using the
supplied Euro connectors and the supplied pre-terminated
network cable is used to integrate the system keypads. Speaker
connections and the network connection are made from the face
of the EZ Port the back of the Essentia, fig. 4. Any CAT5 cable
terminated using 568A or 568B network wiring will suffice should
you need a longer network connection.
SYSTEM
DIGITAL LINK
PROGRAM
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
SYS ON
EXT. MUTE
NETWORK
EZ Port (front)
Essentia Network
Connection
Essentia Speaker
Connection
VI. Attaching Audio Source Equipment to the Essentia Amplifier
Each piece of audio source equipment is connected to the
Essentia amplifier with standard stereo RCA cables. Attach the
RCA cable to the corresponding audio output on the source
equipment and to the desired source input on the back of the
Essentia amplifier, Fig. 5.
SOURCE LINK
SOURCE INPUTS
ZONE 1
ZONE 3
ZONE 2
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
1 2 3 4 5
6
1 2 3 4 5
6
ZONE 1
ZONE 3
ZONE 2
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
Source 1
Tuner 1
Audio
Out
VII. Connecting the IR Emitters
IR commands for the source equipment are transferred from the
Essentia amplifier to the source equipment via mini IR mouse
emitters. Six of these are supplied with your Essentia System.
The emitter is plugged into the corresponding source IR output
on the Essentia and then placed over the IR receiver window on
the source component, fig. 6. The IR outputs are individually
routed to sources 1-6 allowing IR commands from the chosen
source to only control that source.
The two SUM outputs will flash any IR command that is sent from
any of the zones. This is used to connect the NuVo T2 Tuner,
which has a single IR direct input to control both tuners to the
Essentia System or an IR blaster designed to flash IR commands
to a variety of components. This is done by plugging a single
mono 1/8” patch cable into the SUM IR output and into the Direct
IR input.
Fig. 4
Fig. 5
Fig. 6
10
LEFT RIGHT LEFT RIGHT LEFT RIGHT
LEFT RIGHT LEFT RIGHT LEFT RIGHT
_ _ _ _ _ _
+ + + + ++
_ _ _ _ _ _
+ + + + ++
_ _ _ _ _ _
+ + + + ++
CONNECT TO AMPLIFIER
Expander
NuVoNet
Essentia EZ Port
Model NV-E6DEZP-UK
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 1
ZONE 2
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
VARIABLE
OUT PUT
VARIABLE
OUT PUT
FIX ED
OUT PUT
TIP =L
RIN G=R
TIP =L
RIN G=R
FIX ED
OUT PUT