Nuvo NV-E6DMS-DC Home Theater System User Manual


 
*********************************************************************************
COMMAND: * zone xx MUTE OFF (returns zone output to currently connected source at previous volume
setting).
RESPONSE:
*********************************************************************************
COMMAND: * zone xx BASS EQ with yyy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments.
USE LEAD “0” IN TENS PLACE FOR VALUE LESS THAN 10.
RESPONSE:
NOTE: sending this command to the E6D will override the non-volatile BASS setting (set from keypad) for this zone until power
is cycled.
*********************************************************************************
COMMAND: * zone xx TREBLE EQ with yyy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments.
USE LEAD “0” IN TENS PLACE FOR VALUE LESS THAN 10.
RESPONSE:
NOTE: sending this command to the E6D will override the non-volatile TREBLE setting (set from keypad) for this zone until
power is cycled.
*********************************************************************************
COMMAND: * zone xx SOURCE GROUP ON.
RESPONSE:
NOTE: sending this command to the E6D will override the non-volatile GROUP setting (set from keypad) for this zone until
power is cycled.
*********************************************************************************
COMMAND: * zone xx SOURCE GROUP OFF.
RESPONSE:
NOTE: sending this command to the will override the non-volatile GROUP setting (set from keypad) for this zone until power is
cycled.
*********************************************************************************
COMMAND: * zone xx VOLUME RESET ON.
RESPONSE:
NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP
switches) for this zone until power is cycled.
*********************************************************************************
COMMAND: * zone xx VOLUME RESET OFF.
RESPONSE:
NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP
switches) for this zone until power is cycled.
*********************************************************************************
COMMAND: * zone xx KEYPAD LOCK ON This will INHIBIT ANY keypad control input on the zone. This is
the same as activating the Parental lock control at a keypad by holding down a SOURCE key for three
seconds).
RESPONSE: #
ZxxMTOFF<CR>
Same response as for *ZxxCONSR<CR>
ZxxBASSyyy<CR>
Same response as for *ZxxSETSR<CR>
ZxxTREByyy<CR>
Same response as for *ZxxSETSR<CR>
ZxxGRPON<CR>
Same response as for *ZxxSETSR<CR>
ZxxGRPOFF<CR>
Same response as for *ZxxSETSR<CR>
ZxxVRSTON<CR>
Same response as for *ZxxSETSR<CR>
ZxxVRSTOFF<CR>
Same response as for *ZxxSETSR<CR>
ZxxLKON<CR>
ZxxLKON<CR>6
26