Monster Cable 2600 MKII Home Theater System User Manual


 
7
HTS 2600 MKII POWERCENTER FEATURES
1. Current Usage Indicating LED‘s: Indicates and amperage draw.
2. “Ground OK” Indicator: Indicates the PowerCenter is plugged into a properly grounded 120V AV outlet.
3. “Wiring OK” Indicator: Indicates if the Line and Neutral wires from the wall outlet to the PowerCenter
are reversed. Please consult your electrician to correct this immediately.
4. “Clean Power On” Indicator: Indicates Monster Clean Power circuitry is functioning properly.
5. “Switched On” Indicator: Indicates power is being supplied to the switched outlets.
6. “Timed On” Indicator: Indicates power is being supplied to outlets with the sequential turn-on feature.
7. “Sequential Power On/Off” Button: Turns on and off outlets programmed as “SWITCHED ON”
or “SWITCHED ON AFTER DELAY”.
8. “Input Voltage” Indicating LEDs: Indicates that the incoming voltage is within the allowed range of 90V AC
to 140V AC.
9. Ground Terminal: Provides a ground reference point for any ungrounded components.
10. Video Filter (Unswitched Outlets): These outlets have a specifically designed filter circuit that reduces
interference to your video components.
11. Analog Audio Filter (Switched Outlets): These outlets have a specifically designed filter circuit
that reduces interference to your audio components.