Marmitek AWM2 Satellite Radio User Manual


 
Usage of the MicroModules in a 3 phase installation.
The X10 transmitters of the MicroModules transmit the command
only once for use in the phase of which they are connected. When
you want to receive the commands on your other phases as well, you
will need to install the CAT3000 phase coupler/repeater.
Technical specifications
Power 230V, 50Hz
Supply current < 30 mA capacitive
Appliance module 16 A
Signal transmission > 5Vpp in 5Ohm at 120 kHz ±1 kHz
according to EN50065-1, EN50065-2-1,
EN50065-4-1
X10 transmission 1 pulse burst at 0° and 180°
Signal sensitivity 25mVpp … 6Vpp at 120 kHz ± 4kHz
Signal to Noise ratio 1,35 : 1
Connections up to 2,5 mm
2
Approvals NEN-EN-IEC 60669-2-1 and
NEN-EN-IEC 60669-2-2
Made in Holland
10 MARMITEK