Madrigal Imaging BPA 3 Stereo Amplifier User Manual


 
14
Remote turn-on
tip polarity
Your Proceed dealer can help you take advantage of these design features
to maximize your system’s versatility.
3 AC MAINS FUSE
One fast-blow fuse is located on the rear panel of the BPA. If it should be-
come necessary, replace the fuse with the same type only. Refer to the fol-
lowing table for replacement values.
BPA 2 BPA 3
100V to 120VAC 8 amp 12 amp
200V to 240VAC 4 amp 6 amp
Caution! ALWAYS remove the AC cord before removing the fuse!
4 SPEAKER BINDING POSTS
The Proceed BPA is equipped with gold-plated, high-current binding posts
for output termination to a loudspeaker system. To take full advantage of
the AMP’s sonic quality, we recommend using high-quality speaker cable;
we suggest you see your Proceed dealer for specific recommendations.
Caution! NEVER connect the Proceed BPA output terminals to any
device other than a loudspeaker.
NEVER short-circuit the amplifier’s output terminals.
NEVER connect the left-channel output terminals to the right-
channel output terminals.
There are two recommended methods for connecting speaker cables to the
Proceed BPA. A high-quality spade lug or hook lug, soldered to the cable
(or crimped with extremely high pressure, or both) is best.
Connect the left-channel + (positive or red) output post of the Proceed BPA
to the + (positive or red) input terminal of the appropriate loudspeaker.
Connect the left-channel (negative or black) output post of the BPA to the
(negative or black) input terminal of the appropriate loudspeaker.
Repeat this procedure for the remaining channel(s).