Inlet:
hot
water
Inlet:
cold
water
with integrated by-pass -
twin ell not required
Rough in:
K.37.P4.02.931.23
Trim set:
KWC MARLINO
K.21.P4.00
Rough in:
K.37.P4.01.931.23
4 port with diverter
Trim set:
KWC MARLINO
K.20.P4.00
Rough in:
K.37.P4.03.931.23
Trim set:
KWC MARLINO
K.21.P4.00
+
4 port without diverter
/
3 port
802 141
Installation and service instructions
03/00
KWC
MARLINO
Concealed pressure balanced bath and shower mixer
This product is precision engineered to provide superior
performance provided it is installed and operated in
accordance with these recommendations. In order to
fully enjoy the comfort, safety and reliability of your
pressure balancing valve, be certain to familiarize yourself with these
instructions.
Failure to follow these instructions may cause damage or improper
operation and nullify the warranty!
Maintenance:
A) To clean your faucets and accessories simply wipe them with a
wet, soapy cloth, immediately rinse off with cold watre and wipe dry with
a soft, damp cloth or towel.
B) Most bathroom and kitchen cleaners contain aggressive
(acidic / corrosive) chemicals or abrasives which will harm the
finish and cause operational problems.
C) Use of these products voids the manufacturer's warranty.
!
Operation:
A counterclockwise rotation opens the valve beginning with cold water.
Preventing accidental scalding.
An adjustable hot limit stop reduces risk of exposure to extremely hot
water.
Clockwise rotation of the handle closes the valve.
The valve's comfort zone ensures a safe,
reliable and precise adjustment of mixed
water temperature in the range from
95° F (35°C) to 105°F (40°C).
The featherlight touch of the handle
provides simple and easy control for
the young or elderly.
Schweiz, Suisse:
KWC AG
Hauptstrasse
CH-5726 Unterkulm
Tel. : 062 768 67 77
Fax : 062 768 61 62
USA:
KWC FAUCETS INC.
1770 Corporate Drive # 580
Norcross, GA 30093
Phone: 678 334 2121
Fax: 678 334 2128
!
Operating data
Ideal operating pressure : 3 bar (45 PSI)
Max. operating pressure : 5 bar (70 PSI)
Equal pressures cold/warm recommended
Ideal water temperature : 65 °C (149°F)
Max. hot water temperature : 90 °C (194°F)
Attention:
Before installation flush pipes thoroughly!
E
KWC
C
o
m
f
o
r
t
z
o
n
e
105˚F
40˚C
95˚F
35˚C
A
RMATUREN
ROBINETTERIE
RUBINETTERIA
GRIFERIA
FAUCETS