Kramer Electronics TP-100 Satellite Radio User Manual


 
Connecting a XGA/CAT5 Distribution System
5
5 Connecting a XGA/CAT5 Distribution System
To configure a XGA/CAT5 distribution system consisting of two TP-100
XGA Line Transmitter units and two (transceiver) TP-200 XGA Line Receiver
units, as Figure 3 illustrates, do the following:
1. Connect a XGA source (for example, a laptop
1
) to the XGA Input
connector on the first TP-100 XGA Line Transmitter unit.
2. Connect the first TP-100 XGA Line Transmitter unit’s XGA Loop
connector to the XGA Input connector on the second TP-100 XGA Line
Transmitter unit
2
.
3. Connect the first TP-100 XGA Line Transmitter unit’s Line 1 OUT
connector to the Line IN connector on the first TP-200 XGA Line
Receiver unit.
4. Connect the first TP-100 XGA Line Transmitter unit’s Line 2 OUT
connector to the Line IN connector on an additional TP-200 XGA Line
Receiver unit.
5. Connect the first TP-200 XGA Line Receiver unit’s Line OUT connector
to the Line IN connector on the second TP-200 XGA Line Receiver unit.
6. Connect the XGA outputs on both TP-200 Line Receiver units to their
respective XGA acceptors.
7. Connect the power cord on each unit to the electricity supply.
1 Push in the ID Bit button to ON
2 Release the Term button to HI-Z on the first unit and push in the Term button to 75 on the second unit