Kenwood VR61 Speaker System User Manual


 
8 – VR61 and VR62
VR61 and VR62 – 9
4. CONNECTIONS
WARNING: To prevent the risk of electric shock, do not connect the loudspeaker
with the amplier switched on. The protective cover over the terminal strip is a safety
feature per CE requirements. Replace this cover after making the signal connections.
1. Remove the insulating cover from the loudspeaker input
terminal strip.
2. The positive (+) input terminal of the loudspeaker connects
to the positive (+) output of your power amplier.
3. The negative (–) terminal of the loudspeaker connects to
the negative (–) output of your power amplier.
4. Using a small phillips screwdriver, secure the connections.
5. Replace the insulating cover over the loudspeaker input
terminal strip.
Loudspeaker Cables
Use loudspeaker cables with a minimum
conductor size for the length you need as
listed in these tables. This will minimize
power losses to less than 0.5 dB. The
cable lengths listed are “up to” lengths.
For in-between lengths, use the next larger
conductor gauge. Using larger than the
recommended conductor size is always
permissible. Using smaller than recommended
conductor size will result in higher power
losses.
The recommended conductor gauges are
listed for AWG (American Wire Gauge) and
Metric WG (Metric Wire Gauge). Note that
smaller AWG numbers = larger conductors
and smaller Metric WG numbers = smaller
conductors. The Metric WG is equal to ten
times the nominal conductor diameter in millimeters.
For cable lengths over 200 feet / 60 m at 8 ohms, and over 100 feet / 30 m at 4 ohms,
the conductor sizes needed for less than 0.5 dB power losses are rarely practical
for physical and cost reasons. As a practical compromise for these situations the
recommended conductor gauge is 10 AWG or 25 metric.
AMP
XVR
LF
HF
CAUTION:
SUSPENDING THIS SYSTEM SHOULD BE DONE BY QUALIFIED
TECHNICIANS FOLLOWING APPROPRIATE SAFETY STANDARDS
--
+
IN
P
UT
Minimum AWG 4 ohm 8 ohm
18 10 ft 25 ft
16 25 50
14 25 75
12 50 125
10 100 200
Min Metric WG 4 ohm 8 ohm
12 3 m 8 m
14 8 15
16 8 25
20 15 40
25 30 60