Installation of the S5160 is a straightforward process.
IMPORTANT:
The amplifier must be installed
following
the directions described below. To
ensure adequate performance and safety, never
install the amplifier with less free space around the
amplifier than that specified.
IMPORTANT:
For rack mounting, we recommend
using 10-32, 1"-long screws.
NOTE: Heavy equipment should not be supported
solely by the front mounting locations. It is recom-
mended that additional rear support be used.
1
. The S5160 power amplifier has been designed to be
mounted in EIA standard racks or stacked freestanding
as long as there is 4 inches (10cm) of free space around
the amplifier (top, sides and rear). If the S5160 is being
mounted in a rack, it is suggested that its feet be removed
prior to installation. If the S5160 will be stacked with other
components, use the feet that came attached to the unit.
This will ensure that there is sufficient air space underneath
so that heat can be dissipated effectively.
2
. Make sure that the amplifiers are located in a well-
ventilated, cool area. Be certain that the front and rear
panels are not obstructed, as the cooling fan brings air in
from the front and expels it at the rear. It is very important
not to obstruct the airflow from the center front panel;
heat buildup and premature failure may occur.